How to calculate and use Rife frequency

I will explain on the basis of my Rife device. It is not applicable to spooky2 rife devices and other rife devices similar to spooky2.

There are two main types of rife equipment I made:

One is RPX V2.0, which belongs to electrode type rife equipment. It inputs the treatment frequency to the body through electrode pads or other electrodes. This treatment frequency is generated by modulating and amplifying the circuit in the RPX through the fixed carrier frequency and the frequency set by the signal generator.

The other is MOPA, which belongs to plasma rife equipment, which has the same principle as the original rife equipment. It radiates the treatment frequency through the lamp tube filled with rare gas. The treatment frequency is generated by modulating and amplifying the circuit in the MOPA through the fixed carrier frequency and the frequency set by the signal generator. The fixed carrier frequency can also be set to any frequency between 1.8-3.1MHZ via the knob on the MOPA panel.

The common point of the two devices is that they have a carrier frequency and a frequency set by the signal generator. The carrier frequency is generally in the MHz range, and this frequency cannot be heard; the frequency set by the signal generator is generally in the KHz range, and sometimes it can be set to Hz. Most of these frequencies can be heard by the ears because they are also called audio. These two frequencies must be remembered, and they will be used in the following explanation.

(Under a little bit of science here, MHz stands for one million hertz, KHz stands for kilohertz, and Hz stands for one hertz. For example, 2MHz means two million hertz, which is equal to 2000KHz; 2KHz is equal to 2000Hz; 2Hz is equal to 2 Hz.)

————————————————– ——————–

Let’s talk about the rife frequency shared online.

The rife frequency shared online can also be divided into two types according to the frequency, one is greater than 100KHz, the other is less than 100KHz.

In addition, what is Rife’s original frequency? The meaning of Rife’s original frequency is the frequency used by Rife’s experimental equipment and treatment equipment (used by doctors) in his laboratory. Both frequencies are Rife’s original frequency. Due to the difference between experimental equipment and therapeutic equipment, even if it kills the same kind of germs, the frequency of use of the two is different. The experimental equipment in the laboratory has long been lost due to the technical details of the manufacturing, so most of the rife equipment is currently based on the improvement of the treatment equipment.

Rife original frequency link: https://www.zyneng.com/?p=1294

—————————————————————————————————–
Let’s talk about frequency calculation and usage methods in detail below

First, let’s talk about the frequency calculation method used by Rife’s original treatment equipment. To put it simply, it is the harmonic and sideband method. What is a harmonic and what is a sideband can be popularized by yourself. I will mainly talk about how to use this method.

for example:

Example 1. When the treatment frequency you get is greater than 100KHz, for example, the treatment frequency is 210KHz, and the carrier of your device is 3MHz. How to calculate the frequency to be set by the signal generator at this time?

First of all: 210KHz×14=2940KHz=2.94MHz Some people may ask why not multiply by 15 or 13, because the result of multiplying by 14 is the closest to 3MHz.

Next step: 3MHz=3000KHz, 3000KHz-2940KHz=60KHz

Finally, the frequency that the signal generator needs to be set is: 60KHz is the first choice, followed by 60KHz÷2=30KHz, and again 60KHz÷3=20KHz, and the divisor is generally within 35. It should be noted that the smaller the divisor, the better the treatment effect produced by the frequency. Secondly, the choice should be based on the allowable input frequency range of the rife device.

The allowed input frequency range of MOPA equipment is within 100KHz, so as long as the result you get is within 100KHz, you can set it directly in the signal generator. Generally, the frequency sweep function of the signal generator is used. For example, if you want to use 60KHZ, the frequency range is set to 54KHz-66KHz, which is the upper and lower 10% frequency range.

The allowable input frequency range of the RPX device is within 500KHz, so as long as the result you get is within 500KHz, you can set it directly in the signal generator. Generally, the frequency sweep function of the signal generator is used. For example, if you want to use 60KHZ, the frequency range is set to 54KHz-66KHz, which is the upper and lower 10% frequency range. At the same time, you can directly input 210KHz.

Example 2. When the treatment frequency you get is greater than 100KHz, for example, the treatment frequency is 11.04MHz, and your device carrier is 3MHz, how to calculate the frequency to be set by the signal generator at this time?

First: 11.04MHz÷4=2760KHz=2.76MHz At this point, the result is closest to 3MHz.

Next step: 3MHz=3000KHz, 3000KHz-2760KHz=240KHz

Finally, the frequency that the signal generator needs to be set is: 240KHz is the first choice, 240KHz÷2=120KHz, and 240KHz÷3=80KHz. The divisor is generally within 35. It should be noted that the smaller the divisor, the better the treatment effect produced by the frequency. Secondly, the choice should be based on the allowable input frequency range of the rife device.

The allowed input frequency range of MOPA equipment is within 100KHz, so as long as the result you get is within 100KHz, you can set it directly in the signal generator. Generally, the frequency sweep function of the signal generator is used. For example, if you want to use 80KHZ, the frequency range is set to 72KHz-88KHz, which is the upper and lower 10% frequency range.

The allowable input frequency range of the RPX device is within 500KHz, so as long as the result you get is within 500KHz, you can set it directly in the signal generator.

Example 3. When the treatment frequency you get is less than 100KHz, for example, the treatment frequency is 20KHz, and the carrier of your device is 3MHz. How to calculate the frequency to be set by the signal generator at this time?

At this time, there is no need to calculate, directly set the frequency range of the sweep.

The allowed input frequency range of MOPA equipment is within 100KHz, therefore, the sweep frequency range is set to 18KHz-22KHz, that is, the upper and lower 10% frequency range.

The allowable input frequency range of the RPX device is within 500KHz, and the setting is the same as that of the MOPA device.

———————————————————————————
This is basically the calculation and use of RIFE frequency.